Acrartex Float-Free 406 Memory Capsule Bedienungsanleitung Seite 12

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 35
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 11
8 Y1-03-0202 Rev. E
Download from the beginning of memory to current write location
This option reads the Main Memory area starting at the first address in
the partition and ending at the current write location. This can be
used to read back a compete file when used in conjunction with the
data upload option ‘Force RLB-35MC Pointer Reset’.
Download the complete memory from start to end
This option also reads all of the Main Memory area but starts at the
first address in the partition and ends at the last address.
Reading a File
After the download mode is selected, click the ‘Receive Data’ button.
Each time this option is selected the user will be prompted for the
name of a file to save the data to.