12 Y1-03-0202 Rev. E
Bytes 0 – 6, 10, and 11 are part of the command string sent by the
user to the RLB-35MC Memory Board. Bytes 7 – 9 and 12 – 14 are
returned by the RLB-35MC Memory Board with the echoed command
string in response to a ‘Test’ command (‘E’ command and ‘0’
subcommand); only bytes 12 and 13 are returned with the command
string in response to a ‘Status’ command (‘S’ command).
6.2. Header
The first four (4) bytes are a fixed value header with hexadecimal
values of AC, 53, CA, 35.
6.3. Operation Command
Byte 4 is the Operation Command and is in ACSII format:
If main memory, read the read offset specified number MB of data, else
read & return all the data from the specified memory partition.
Write into the specified memory partition
Read all of main memory starting at the specified read offset from the
current write address and ending at the address just before the stating
address
Read main memory from the partition’s beginning address to the current
write address
Read all of main memory starting at the partition’s beginning address to
the ending address
Request the memory board status
Request the memory board status, CFC size, & software version
6.4. Operation Subcommand
Byte 5 is the Operation Subcommand, and is in ASCII format. It
defines which partition of memory each read or write command will
operate on.
Configuration memory partition